CT SCANNER

GE Revolution ACTs Es, Ex & Expert Edition

Specification Parameter
Gantry Aperture 63 cm
Gantry Tilt Software Tilt
Scan Thickness 0.625, 1.25, 2.5, 3.75, 5.0, 7.5, 10.0 mm
Scan Speed 0.98, 1, 1.5, 2.0, 3.0, 4,0Sec
Scan KVP 80,100, 120,140 Kv
Scan mA Upto 200 mA
Tube Capacity 2.0 Mhu
Detector Type Clarity Panel Detector
Scan FOV 1.25,5.0,10.0 cm
Dicom In built
Recommended Below 40 Cases
...

GE Light Speed VCT 64 Slice

Specification Parameter
Gantry Aperture 70 cm
Gantry Tilt 30 – +
Scan Thickness 0.65,1,25,2.5,5 mm
Scan Speed 0.4 – 2 Sec
Scan KVP 80, 100,120,140
Scan mA Upto 700 mA
Tube Capacity 8 mhu
Tube Name Performix Pro 100
Detector Type Solid State Array
Power Supply 10 KVA
Scan FOV 50cm
Dicom YES
Recommended Below 80 Cases
...

Light Speed VCT 16 Slice

Specification Parameter
Gantry Aperture 70 cm
Gantry Tilt 30
Scan Thickness .625, 1.25, 2.5
Scan Speed 3.75, 5, 7.5, 10 mm 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3
Scan KVP 80, 100,120,140 Kv
Scan mA Upto 700 mA
Tube Capacity 6.3 mhu
Detector Type 16 X 912 ROWS
Power Supply 10 KVA
Scan FOV 25, 50
Dicom In built
Recommended Below 100 Cases
...

Light Speed Ultra 8 Slice

Specification Parameter
Gantry Aperture 70 cm
Gantry Tilt 30 – +
Scan Thickness .625, 1.25, 2.5, 3.75, 5, 7.5 MM
Scan Speed 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3
Scan KVP 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3
Scan mA Upto 440 mA
Tube Capacity 6.3 mhu
Detector Type 8 X 912 ROWS
Scan FOV 25, 50
Dicom In built
Recommended Below 75 Cases
...

Light Speed QXI 4 Slice Spiral

Specification Parameter
Gantry Aperture 70 cm
Gantry Tilt 30
Scan Thickness 0.5, 0.6, 0.7, 0.8, 0.9, 1, 2, 3, 4
Scan Speed 0.63, 1.25, 2.5, 3.75, 7.5, 10 Sec
Scan KVP 80, 100,120,140 Kv
Scan mA Upto 440 mA
Tube Capacity 6.3 mhu
Detector Type Four rows of HR detectors
Scan FOV 25, 50
Dicom In built
Recommended Below 50 Cases
...

Hi Speed NXI-NXI Pro – CT/e 2 Slice Spiral

Specification Parameter
Gantry Aperture 70 cm
Gantry Tilt 30 – +
Scan Thickness 0.5, 1, 2, 3, 4, 5, 6, 7, 10 mm
Scan Speed 0.7, 1, 1.5, 2, 3 Sec
Scan KVP 80, 120,140 Kv
Scan mA Upto 440 mA
Tube Capacity 6.3 / 3.5 / 2.0 Mhu
Detector Type Two rows of HR
Power Supply 10 KVA
Scan FOV 18, 25, 35, 50 cm
Dicom In built
Recommended Below 40 Cases
...

HiSpeed LXI – DXI FXI – ZXI – CT/e Fast Single Slice

Specification Parameter
Gantry Aperture 65 / 70 cm
Gantry Tilt 30
Scan Thickness 65 / 70 cm
Scan Speed 0.8, 1,1.5,2,3 sec
Scan KVP 80, 120,140 Kv
Scan mA Upto 350 mA
Tube Capacity 2 / 3.5 / 6.3 mhu
Detector Type Solid state detector
Scan FOV 18, 25, 42, 50 cm
Dicom In built
Recommended Below 30 Cases
...

Prospeed Single Slice Spiral C T

Specification Parameter
Gantry Aperture 68 cm
Gantry Tilt 25
Scan Thickness 1,2,3,5,7,10 mm
Scan Speed 1.5,2,3 sec
Scan KVP 80, 120,140 Kv
Scan mA Upto 350 mA
Tube Capacity 3.5 mhu
Detector Type Soild State / xenon
Scan FOV 25,35,42,50 cm
Dicom Optional
Recommended Below 25 Cases
...